Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Cureus ; 15(2): e35529, 2023 Feb.
Article in English | MEDLINE | ID: covidwho-2308789

ABSTRACT

Background Considering the virulent nature of the COVID-19, the safety of healthcare workers (HCW) became a challenge for hospital administrators. Wearing a personal protective equipment (PPE) kit, called donning, which can be easily done by the help of another staff. But correctly removing the infectious PPE kit (doffing) was a challenge. The increased number of HCWs for COVID-19 patient care raised the opportunity to develop an innovative method for the smooth doffing of PPEs. Objective We aimed to design and establish an innovative PPE doffing corridor in a tertiary care COVID-19 hospital during the pandemic in India with a heavy doffing rate and minimize the COVID-19 virus spread among healthcare workers. Methodology A prospective, observational cohort study at the COVID-19 hospital, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India, was conducted from July 19, 2020, to March 30, 2021. The time taken for PPE doffing process of HCWs was observed and compared between the doffing room and doffing corridor. The data was collected by a public health nursing officer using Epicollect5 mobile software and Google forms. The following parameters, like grade of satisfaction, time and volume of doffing, the errors in the steps of doffing, rate of infection, were compared between the doffing corridor and the doffing room. The statistical analysis was done by the use of SPSS software. Result 'Doffing corridor' decreased the overall doffing time by 50% compared to the initial doffing room. The doffing corridor solved the purpose of accommodating more HCWs for PPE doffing and an overall saving of 50% time. Fifty-one percent of HCWs rated the satisfaction rate as Good in the grading scale. The errors in the steps of doffing that occurred in the doffing process were comparatively lesser in the doffing corridor. The HCWs who doffed in the doffing corridor were three times less likely to get self-infection than the conventional doffing room. Conclusion Since COVID-19 was a new pandemic, the healthcare organizations focused on innovations to combat the spread of virus. One of these was an innovative doffing corridor to expedite the doffing process and decrease the exposure time to the contaminated items. The doffing corridor process can be considered at a high-interest rate to any hospital dealing with infectious disease, with high working satisfaction, less exposure to the contagion, and less risk of infection.

2.
Diagnostics (Basel) ; 13(3)2023 Jan 18.
Article in English | MEDLINE | ID: covidwho-2199881

ABSTRACT

The rapid increase in the number of CT acquisitions during the COVID-19 pandemic raised concerns about increased radiation exposure to patients and the resultant radiation-induced health risks. It prompted researchers to explore newer CT techniques like ultra-low dose CT (ULDCT), which could improve patient safety. Our aim was to study the utility of ultra-low dose CT (ULDCT) chest in the evaluation of acute COVID-19 pneumonia with standard-dose CT (SDCT) chest as a reference standard. This was a prospective study approved by the institutional review board. 60 RT-PCR positive COVID-19 patients with valid indication for CT chest underwent SDCT and ULDCT. ULDCT and SDCT were compared in terms of objective (noise and signal-to-noise ratio) and subjective (noise, sharpness, artifacts and diagnostic confidence) image quality, various imaging patterns of COVID-19, CT severity score and effective radiation dose. The sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy of ULDCT for detecting lung lesions were calculated by taking SDCT as a reference standard. The mean age of subjects was 47.2 ± 10.7 years, with 66.67% being men. 90% of ULDCT scans showed no/minimal noise and sharp images, while 93.33% had image quality of high diagnostic confidence. The major imaging findings detected by SDCT were GGOs (90%), consolidation (76.67%), septal thickening (60%), linear opacities (33.33%), crazy-paving pattern (33.33%), nodules (30%), pleural thickening (30%), lymphadenopathy (30%) and pleural effusion (23.33%). Sensitivity, specificity and diagnostic accuracy of ULDCT for detecting most of the imaging patterns were 100% (p < 0.001); except for GGOs (sensitivity: 92.59%, specificity: 100%, diagnostic accuracy: 93.33%), consolidation (sensitivity: 100%, specificity: 71.43%, diagnostic accuracy: 93.33%) and linear opacity (sensitivity: 90.00%, specificity: 100%, diagnostic accuracy: 96.67%). CT severity score (range: 15-25) showed 100% concordance on SDCT and ULDCT, while effective radiation dose was 4.93 ± 1.11 mSv and 0.26 ± 0.024 mSv, respectively. A dose reduction of 94.38 ± 1.7% was achieved with ULDCT. Compared to SDCT, ULDCT chest yielded images of reasonable and comparable diagnostic quality with the advantage of significantly reduced radiation dose; thus, it can be a good alternative to SDCT in the evaluation of COVID-19 pneumonia.

3.
Cureus ; 14(9): e29721, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-2110928

ABSTRACT

BACKGROUND: Non-invasive oxygen therapy (NIT) consists of high-flow nasal oxygen (HFNO) and continuous positive airway pressure (CPAP). NIT is routinely being used for the management of acute respiratory failure secondary to coronavirus disease-2019 (COVID-19) with variable outcomes. However, previously published studies show that NIT failure might delay endotracheal intubation and invasive mechanical ventilation and results in worse outcomes in patients with hypoxemic respiratory failure. Early prediction of failure of NIT, will help in early decision-making in initiating invasive mechanical ventilation. We retrospectively studied the predictors for NIT failure in patients with moderate to severe COVID-19. METHODS: Adult patients (>18 years) admitted to the intensive care unit (ICU) with moderate to severe COVID-19 ARDS and received NIT [HFNO and CPAP non-invasive ventilation (NIV)] were included in this study. Baseline clinical and laboratory data were collected retrospectively from the electronic hospital information system. NIT failure was defined as the need for invasive mechanical ventilation after the initiation of NIT in the ICU. Univariate and multivariate logistic regression analyses were used to find out the possible predictors of NIT failure. RESULTS: Out of 254 patients admitted to ICU, 127 patients were initiated NIT at admission to ICU. During the course of the ICU stay, 33 (26%) patients subsequently required invasive mechanical ventilation (NIT failure). Respiratory rate-oxygenation index (ROX index) of <2.97 at two hours and <3.63 at six hours of ICU admission predicted NIT failure in our cohort of patients with a high positive predictive value. CONCLUSION: Patient selection is crucial for successful NIT in COVID-19. Application of ROX index measured in the first six hours of ICU admission helps in the identification of patients at risk of NIT failure with moderate to severe COVID-19 ARDS.

4.
Indian J Crit Care Med ; 26(3): 403-404, 2022 Mar.
Article in English | MEDLINE | ID: covidwho-1742858

ABSTRACT

Muthu V, Sehgal IS, Dhooria S, Prasad KT, Aggarwal AN, Agarwal R. Corticosteroids for Non-severe COVID-19: Primum Non Nocere. Indian J Crit Care Med 2022;26(3):403-404.

5.
Cureus ; 13(9): e17756, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1438875

ABSTRACT

Background Survivors of COVID-19 pneumonia may have residual lung injury and poor physical and mental health even after discharge. We hypothesized that COVID-19 severe acute respiratory distress syndrome (ARDS) patients needing mechanical ventilation may be at a greater risk of deterioration in pulmonary function, mental health, and quality of life (QOL). This study analyses the differences in pulmonary function, mental health, and QOL after recovery, in patients having received non-invasive oxygen therapy versus invasive mechanical ventilation during ICU stay. Methods Patients aged >18 years, who had completed 3 months post ICU discharge, with moderate to severe COVID-19 ARDS, were consecutively enrolled from May 1 to July 31, 2021. Patients were allocated into Group A - having required high flow nasal cannula (HFNC)/non-invasive ventilation (NIV) and Group B - having received invasive mechanical ventilation. Pulmonary function tests, 6-minute walk test (6-MWT), and health-related quality of life were compared. Results Of the 145 eligible patients, 31 were lost to follow-up and 21 died. Seventy-four patients were allocated into Groups A (57 patients) and B (17 patients). In Group A, abnormal forced expiratory volume in first second (FEV1), forced vital capacity (FVC), forced expiratory flow in mid-half of FVC (FEF25-75), and peak expiratory flow rate (PEFR) values were obtained in 27 (47.37%), 43 (75.44%), 11 (19.3%), and 25 (43.86%) patients, and in Group B, in 13 (76.47%), 17 (100%), 1 (5.88%), and 8 (47%) patients, respectively. No patient had abnormal FEV1/FVC. All Group B patients had a restrictive pattern in spirometry as compared to 77% in Group A. Group B had a lower arterial partial pressure of oxygen (PaO2) (p=0.0019), % predicted FVC (p<0.0001), % predicted FEV1 (p=0.001), and 6-MWT distance (p<0.001). The physical component score in the short-form survey 12 questionnaire was higher in group A, p<0.001, whereas the mental component score was comparable. Conclusions Patients requiring invasive mechanical ventilation (MV) have a greater risk of impaired pulmonary function and reduced QOL post-ICU discharge. This warrants a greater need for following these patients for better rehabilitation.

6.
J Bronchology Interv Pulmonol ; 28(2): e26-e28, 2021 Apr 01.
Article in English | MEDLINE | ID: covidwho-1254910

Subject(s)
Bronchoscopy , Humans
7.
Indian J Crit Care Med ; 24(6): 485-486, 2020 Jun.
Article in English | MEDLINE | ID: covidwho-806074

ABSTRACT

How to cite this article: Sehgal IS, Yaddanapudi LN, Dhooria S, Thurai Prasad K, Puri GD, Muthu V, et al. Barrier Protection during Airway Intubation. Indian J Crit Care Med 2020;24(6):485-486.

SELECTION OF CITATIONS
SEARCH DETAIL